13 research outputs found

    Long-distance frequency transfer over an urban fiber link using optical phase stabilization

    Full text link
    We transferred the frequency of an ultra-stable laser over 86 km of urban fiber. The link is composed of two cascaded 43-km fibers connecting two laboratories, LNE-SYRTE and LPL in Paris area. In an effort to realistically demonstrate a link of 172 km without using spooled fiber extensions, we implemented a recirculation loop to double the length of the urban fiber link. The link is fed with a 1542-nm cavity stabilized fiber laser having a sub-Hz linewidth. The fiber-induced phase noise is measured and cancelled with an all fiber-based interferometer using commercial off the shelf pigtailed telecommunication components. The compensated link shows an Allan deviation of a few 10-16 at one second and a few 10-19 at 10,000 seconds

    High-resolution microwave frequency dissemination on an 86-km urban optical link

    Full text link
    We report the first demonstration of a long-distance ultra stable frequency dissemination in the microwave range. A 9.15 GHz signal is transferred through a 86-km urban optical link with a fractional frequency stability of 1.3x10-15 at 1 s integration time and below 10-18 at one day. The optical link phase noise compensation is performed with a round-trip method. To achieve such a result we implement light polarisation scrambling and dispersion compensation. This link outperforms all the previous radiofrequency links and compares well with recently demonstrated full optical links.Comment: 11 pages, 5 figure

    86-km optical link with a resolution of 2.10-18 for RF frequency transfer

    Full text link
    RF frequency transfer over an urban 86 km fibre has been demonstrated with a resolution of 2.10-18 at one day measuring time using an optical compensator. This result is obtained with a reference carrier frequency of 1 GHz, and a rapid scrambling of the polarisation state of the input light in order to reduce the sensitivity to the polarisation mode dispersion in the fibre. The limitation due to the fibre chromatic dispersion associated with the laser frequency fluctuations is highlighted and analyzed. A preliminary test of an extended compensated link over 186 km using optical amplifiers gives a resolution below 10-17 at 1 day

    Cold atom Clocks and Applications

    Full text link
    This paper describes advances in microwave frequency standards using laser-cooled atoms at BNM-SYRTE. First, recent improvements of the 133^{133}Cs and 87^{87}Rb atomic fountains are described. Thanks to the routine use of a cryogenic sapphire oscillator as an ultra-stable local frequency reference, a fountain frequency instability of 1.6×1014τ1/21.6\times 10^{-14}\tau^{-1/2} where τ\tau is the measurement time in seconds is measured. The second advance is a powerful method to control the frequency shift due to cold collisions. These two advances lead to a frequency stability of 2×10162\times 10^{-16} at 50,000sforthefirsttimeforprimarystandards.Inaddition,theseclocksrealizetheSIsecondwithanaccuracyof50,000s for the first time for primary standards. In addition, these clocks realize the SI second with an accuracy of 7\times 10^{-16},oneorderofmagnitudebelowthatofuncooleddevices.Inasecondpart,wedescribetestsofpossiblevariationsoffundamentalconstantsusing, one order of magnitude below that of uncooled devices. In a second part, we describe tests of possible variations of fundamental constants using ^{87}RbandRb and ^{133}$Cs fountains. Finally we give an update on the cold atom space clock PHARAO developed in collaboration with CNES. This clock is one of the main instruments of the ACES/ESA mission which is scheduled to fly on board the International Space Station in 2008, enabling a new generation of relativity tests.Comment: 30 pages, 11 figure

    Phase- coherent comparison of two optical frequency standards over 146 km using a telecommunication fiber link

    Get PDF
    We have explored the performance of two "dark fibers" of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physi-kalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw trans-fer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB's Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1E-19, and short term frequency instability given by the fractional Allan deviation of sy(t)=3.3E-15/(t/s)

    High resolution frequency standard dissemination via optical fiber metropolitan network

    No full text
    International audienceWe present in this article results on a new dissemination system of an ultrastable reference signal at 100 MHz on a standard fiber network. The 100 MHz signal is simply transferred by amplitude modulation of an optical carrier. Two different approaches for compensating the noise introduced by the link have been implemented. The limits of the two systems are analyzed and several solutions are suggested in order to improve the frequency stability and to further extend the distribution distance. Nevertheless, our system is a good tool for the best cold atom fountains comparison between laboratories, up to 100 km, with a relative frequency resolution of 10 −14 at 1 s integration time and 10 −17 for 1 day of measurement. The distribution system may be upgraded to fulfill the stringent distribution requirements for the future optical clocks

    Design and realization of a flywheel oscillator for advanced time and frequency metrology

    No full text
    International audienceIn this article, we describe a new frequency synthesis system that includes a low phase noise cryogenic sapphire oscillator (CSO) and an H-maser to provide metrological low-noise signals to time and frequency experiments. Implementing this system as a local oscillator for a Cs cold atom fountain, a record frequency stability of 1.6×10-14tau-1/2 is obtained
    corecore